Starting Time of Fluid Couplings

ToniG
(not verified)
Posted in: , on 5. Jun. 2013 - 16:50

Hi,

I have been looking into the calculation of start-up time of fluid couplings ands i am kind of at my wits end. As there are many factors that needs to be considered (Mass moment of inertias, oil filling level, motor....) I was wondering if there is any reliable method to approach the calculation.

Thanks

Starting Time Of Fluid Couplings

Erstellt am 5. Jun. 2013 - 05:35

ToniG

Please improve your Forum registration form so that we know at which University you study, etc.

Thanks.

Dr. Wohlbier

Administrator

Starting Time Of Fluid Couplings

Erstellt am 27. Jul. 2013 - 01:50

F=ma. The motor and motor side fluid coupling half will start without the load as the connecting vortices have not initially formed. The inertias to overcome in this phase are those of the motor and fluid coupling half. With the motor rotating at full speed and no load the vortices form and engage the conveyor load. For starting time in this case we must know the fluid couplings slip load then apply it against the remaining conveyor inertias and loads.

Joe Dos Santos

Dos Santos International 531 Roselane St NW Suite 810 Marietta, GA 30060 USA Tel: 1 770 423 9895 Fax 1 866 473 2252 Email: jds@ dossantosintl.com Web Site: [url]www.dossantosintl.com[/url]